17.3 Phases of the diagnostics test
Irrespective of the type of electronic board and of the selector configuration, once the diagnostics system has
been activated, turn the selector dial clockwise to run a check of the various components and read the alarms
(as described in table 1).
Concurrently, a control code of the selector (or of the second selector, where envisaged) is shown: in Z3
stylings on the display for two seconds, before displaying the contents of the last column in the table below,
whereas in Z6 stylings the code is displayed by the LEDs coming on for three seconds (see table 2).
All alarms are enabled in the diagnostic cycle.
TABLE 1
Selector
position
Components activated Working conditions Function tested
When a Display
is present
1
- All the LEDs come on in
sequence.
- Pressing a button turns on
the corresponding group or
LED.
Always active
User interface
functioning
2
- Door safety interlock
- Wash solenoid valve
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Water fill to wash
compartment
Water level in
the tub (mm)
3
- Door safety interlock
- Pre-wash solenoid valve
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Water fill directly
to tub
Water level in
the tub (mm)
4
- Door safety interlock
- Solenoid valve
pre-wash and wash
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Water fill to
conditioner
compartment
Water level in
the tub (mm)
6
- Door safety interlock
- Wash solenoid valve, if the
water in the tub is not
enough to cover the heating
element
- Heating element
Door closed
Water level above the
heating element.
Maximum time
10 mins up to 90°C.
(*)
Reheating
Temperature in
°C measured
using the NTC
probe.
7
- Door safety interlock
- Wash solenoid valve if the
water level in the tub does
not cover the heating
element
- Motor (55 rpm clockwise,
55 rpm anticlockwise, pulse
at 250 rpm)
Door closed
Water level above
the heating element
Check for leaks
from the tub.
Drum speed in
rpm/10
8
- Door safety interlock
- Drain pump
- Motor up to 650 rpm then at
maximum spin speed. (**)
Door closed
Water level lower
than anti-boiling level
for spinning
Drain, calibration
of analogue
pressure switch
and spin
Drum speed in
rpm/10
9
----
----
----
----
10
- Reading/Deleting the last alarm
----- ----
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining the
water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is
higher than 80
°C, heating does not take place).
(**) The check at the maximum speed occurs without control of the AGS (anti-unbalancing system) and no garments must be inside the