Alarm
Code
Alarm Description Fault Condition Possible Fault Machine Action/Status Reset Key
EF6 Safety reset
MB microcontroller
damaged
Main Board defective
No actions to be performed. If
still present replace the Main
Board
-
EB1
EH1
Appliance power supply
frequency out of limits
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
frequency
ON/OFF
EB2
EH2
Supply voltage too high
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
voltage conditions.
ON/OFF
EB3
EH3
Supply voltage too low
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
voltage conditions.
ON/OFF