487 03 29 41
5
47. Gas System
Service-
manual
47
Measuring tap, supply pressure (pos. 6)
Refer to the installation manual for the proper supply pressure for
the type of gas being used.
1. Turn off the manual gas valve to the machine and the dryer
started on High heat.
2. Loosen the gas pressure tap (pos. 6) one-quarter of a turn and
connect a manometer to the tap.
3. Turn on the manual gas supply valve.
4. Start the dryer on High heat and check that the supply pressure is
within the allowable range.
Note: If the pressure is not within the range specified in the
installation manual,
DO NOT OPERATE THE DRYER.
Contact your gas supplier.
NOTE that the gas supply MUST be turned off before
loosening tap pos. 6 (SUPPLY) or gas will escape.

Table of Contents