7
40. Heating system
Service
manual
40
Steam heated dryers
Description
The steam calorifer A is located in the steam
heating unit at the top of the dryer behind back
plate A, fig. 1.
The air is drawn through the louvres on the back
plate and into the heating unit.
The heated air passes through the garments and
the drum vents.
Then the air flows from the perforation through
the filter and via the outlet to the open air, fig. 2.
Overheating thermostat (also see section 27)
Steam heated dryers are equipped with one
overheating thermostat in the outlet
In the event of overheating, the dryer stops and
E08 flashes in the display.
Reset must be done manually but first the error
must be detected.
The following error code are related to this
section:
E 08 overheating
See Selecta Control service manual.
To be continued on the following page