3.5.5 Main Feedback Cable (Port J3)
The main feedback cable is used to transfer feedback data from the motor to the drive.
The Bassoon accepts the following as a main feedback mechanism:
Incremental encoder only
Incremental encoder with digital Hall sensors
Digital Hall sensors only
Incremental Analog (Sine/Cosine) encoder (option)
Resolver (option)
Tachometer and potentiometer
Absolute encoder
Connect the main feedback cable from the motor to the J3 port on the front of the Bassoon, using
a 12-pin, Molex plug.
Connect the drain wire to pin 4. If the cable has no drain wire, connect the shield to
pin 4.
Ground the shield to the motor chassis.
Figure
3-9: The Main Feedback (J3) Cable
Drain
Wire