A.9.2 Digital Output Interface
Feature Details Connector Location
Type of output
Optically isolated
Open collector and open
emitter
Maximum
supply output
(Vcc)
30 V
Maximum
output current
Io (max) (Vout =
Low)
Iout (max) 10 mA
VOL @
maximum
output voltage
(low level)
Vout (on) 0.3 V + 0.02 * Iout (10
mA)
RL External resistor RL must be selected
to limit output current to no more
than 10 mA.
(max)Io
VOLVcc
R
L
=
Executable time If output is set to one of the built-in
functions — Home flag, Brake or
AOK — execution is immediate
upon detection:
0 < T < 4 x TS
If output is set to General output
and is executed from a program, the
typical time is approximately 0.5
msec.
Rout = 20
Ω
33v
OUTput Ret(i
)
OUTput (i)
HAR
006
1
A
Figure A-3: Digital Output Schematic