1 Remove the belt cover and base (see page 6, 7).
2 Adjust the clearance between the plunger and the
thread cutter solenoid q by moving the thread
cutter solenoid setting plate .
3 Tighten screws w.
4 Attach the belt cover and base.
q Thread cutter solenoid
w Screws
e 2.0mm
Adjusting thread cutter solenoid
The standard clearance between the plunger and the thread cutter solenoid should be 2.0 mm.