Workshop manual
12
CAUTION!
Damaging the display
Never disconnect the starter battery while the engine is running.
Never start the tractor with external power supply.
Charging the starter battery
Charging is required:
Prior to storing for the winter break.
During extended standstill of the machine (longer than 3 months).
DANGER!
Risk of explosion!
The charging current of the charger must not be higher than 5 A and e the maximum permitted
charging voltage is 14.4 V.
We recommend charging the maintenance-free and gas-tight starter battery with a
compatible charger.
Charge the starter battery only in a dry room.
Observe the operating instructions for the battery charger.
Remove the ignition key.
Open the engine cover.
CAUTION!
Danger of short circuit!
Ensure that the polarity is correct.
Red terminal = positive pole (+)
Black terminal = negative pole (-)
Connect the charger terminals to the battery poles.
Connect the charger to the mains, and switch it on.