RRP: Control processor blade (CP8)
105
Removal and Replacement Procedures (RRPs)
<output truncated>
tz ##################################################
mtracer-tool ##################################################
lkcd ##################################################
sysstat ##################################################
Removing unneeded files, please wait ...
Finished removing unneeded files.
All packages have been downloaded successfully.
Firmwaredownload has completed successfully.
2008/07/03-15:05:56, [SULB-1002], 924,, INFO, ED-DCX-4S-B, Firmwaredownload
command has completed successfully.
8. Enter firmwareDownloadStatus to verify that the firmware has
been updated.
9. Enter haEnable to re-enable HA on the active CP blade.
10. Verify that the reboot is complete and the CP blades have
achieved failover redundancy:
a. Wait until the status LEDs on both CP blades are not lit.
b. Enter haShow and verify that the command output
includes “HA Enabled Heartbeat Up”. If not, reenter the
command until you have verified that redundancy is
achieved.
11. Enter firmwareShow to verify that the firmware version has been
updated.
12. Pack the faulty CP blade in the packaging provided with the new
CP blade, and contact EMC Customer Service to determine the
return procedure.
13. Replace the chassis door (“RRP: Chassis door”).

Table of Contents

Other manuals for EMC Connectrix B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Connectrix B Series and is the answer not in the manual?

EMC Connectrix B Series Specifications

General IconGeneral
BrandEMC
ModelConnectrix B Series
CategorySwitch
LanguageEnglish

Related product manuals