130
EMC Connectrix B Series v6.2 ED-DCX-4S-B Hardware Reference Manual
Removal and Replacement Procedures (RRPs)
“Factory Serial Num” and “Serial Num” are listed under
“Chassis/WWN Unit 1.” If the current WWN cards are the
original cards, the factory serial number listed is the same as the
chassis serial number.
switch:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE Slot: 1
Header Version: 2
Power Consume Factor: -50
Factory Part Num: 60-0001532-03
Factory Serial Num: KP000000195
Manufacture: Day: 1 Month: 1 Year: 2007
Update: Day: 14 Month: 3 Year: 2012
Time Alive: 187 days
Time Awake: 3 days
<output truncated>
CHASSIS/WWN Unit: 1 (in same assembly as WWN Unit:
2)
Header Version: 2
Power Consume Factor: -3
Factory Part Num: 60-0001501-07
Factory Serial Num: FT02X805BE2
Manufacture: Day: 26 Month: 3 Year: 2007
Update: Day: 14 Month: 3 Year: 2009
Time Alive: 207 days
Time Awake: 3 days
<output truncated>
switch:admin>
7. Create a SAN “profile” by entering and recording the information
provided by the following commands:
•nsShow
• nsAllShow
• switchShow
• fabricShow
Copy the command output into a text file named “SANbefor.txt”.
After the ED-DCX-4S-B is restored to the fabric, this information
can be used to verify that no unintentional changes have occurred
to the fabric.