Mentor MP Short Form Guide 65
Issue Number: 5 www.controltechniques.com
Safety Information Product information
Mechanical
installation
Electrical
installation
Getting started
Running the motor
SMARTCARD
operation
Advanced
parameters
Diagnostics UL listing
5.3 Menu 0 (sub block)
Menu 0 can be accessed by 2 methods:
1. Pr 11.44 (SE14, 0.35) = 0. Sub block mode.
2. Pr 11.44 (SE14, 0.35) <>0. Linear mode.
Menu 23 contains the parameters to allow menu 0 to be customized in sub block mode.
The first sub block is a user defined area (USEr) which is configured by the parameters
in menu 22. As default there are no parameters configured to the user sub block and so
it is empty. The next 7 sub blocks are pre-defined. Access to the pre-defined blocks is
enabled or disabled by Pr 23.03 to Pr 23.09.
Movement between sub blocks is achieved with the left and right keys.
Pr 23.01 contains all the sub block headers.
Table 5-1 and Figure 5-5 show the result of the direction keys when Pr 11.44 (SE14,
0.35) is set to L1 (0). When Pr 11.44 (SE14, 0.35) is not 0 the left and right keys will
allow access to the advance parameter set and menu 0 will become a linear menu.
Table 5-1 Keypad navigation
When moving to the user block header, the user block header is only displayed if there
are some valid parameters in the block. When moving between pre-defined header
blocks the pre-defined header block is only displayed if the pre-defined block is enabled.
When moving between parameters within a block, only valid parameters are displayed.
When changing the values of parameters, make a note of the new values in case they
need to be entered again.
For new parameter-values to apply after the AC supply to the drive is interrupted, new
values must be saved (section 5.8 Saving parameters on page 74).
Starting location Action Finishing location
Header
Right Next header
Left Previous header
Up First parameter in header block
Down Last parameter in header block
Parameter
Right Next header
Left Previous header
Up Next parameter in header block
Down Previous parameter in header block