EasyManua.ls Logo

Emerson Rosemount 1195 - REMOVE THE TERMINAL BLOCK; REMOVE THE ELECTRONICS BOARD

Emerson Rosemount 1195
229 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-3
REMOVE THE TERMINAL
BLOCK
Electrical connections are located on the terminal block in the
compartment labeled FIELD TERMINALS.
Loosen the two small screws located at the 9 o'clock and 4 o'clock
positions, and pull the entire terminal block out to remove it
REMOVE THE
ELECTRONICS BOARD
The flowmeter electronics board is located in the compartment opposite
the terminal side. To remove the electronics board perform the
following procedure:
1. Remove the housing cover opposite the field terminal side.
2. Loosen the two captive screws that anchor the board to the
housing. The electronics board is electrostatically sensitive;
observe handling precautions for static-sensitive components.
NOTE
If you are disassembling a flowmeter with a LCD meter, loosen the two
captive screws that are visible on the right and left sides of the meter
display. The two screws anchor the LCD meter to the electronics board
and the electronics board to the housing.
3. Slowly pull the electronics board out of the housing. With the two
captive screws free of the flowmeter housing, only the sensor
module ribbon cable holds the board to the housing.