Rosemount Model 1195/ProPlate/Mass ProPlate
10-4
Table 10-4. Assembly Weights, Body
Only.
Table 10-5. Assembly Weights, With
Piping
NOTE
The above dimensions are based on standard model offering.
Torque Values of Standard Bolts
Orifice Body Bolting: Carbon steel: 60 ft.-lb (81 N-m), stainless steel:
34-38 ft.-lb (46-52 N-m).
Transmitter Bolting: Carbon and stainless steel: 34–38 ft.-lb. (46-52
N-m)
3-Valve Manifold Bolting: Carbon and stainless steel: 34–38 ft.-lb
(46-52 N-m).
Straight Pipe Requirements
Figure 10-3 on page 10-5 lists the recommended lengths of straight pipe
for specific flow situations per ISO 5167. Use the appropriate lengths of
straight pipe upstream and downstream from the Model 1195 body to
minimize the effects of moderate flow disturbances in the line.
Piped assemblies incorporate some or all of the recommended lengths.
The Mass ProPlate assembly incorporates some or all of the
recommended straight pipe required lengths, since upstream and
downstream piping sections are standard.
The piping section lengths are referenced in Table 10-3.
See Figure 10-3 to determine if additional pipe length is required for
your given flow situation. Upstream and downstream piping sections
are optional with the ProPlate and Model 1195. If the piping sections
are selected, see Figure 10-3 to ensure that the appropriate lengths of
straight pipe are sufficient for your application.
Assembly Weights, Body Only
Line Size Model 1195 Only ProPlate
lb kg lb kg
½ in. (15 mm.) 4 1.8177.7
1 in. (25 mm.) 6 2.7 19 8.6
1½ in. (40 mm) 8 3.6 21 9.5
Assembly Weights, With Piping
Line Size Model 1195 Only ProPlate Mass ProPlate
150 # 300# 600# 150 # 300# 600# 150 # 300# 600#
lb kg lb kg lb kg lb kg lb kg lb kg lb kg lb kg lb
NJ
½ in. (15 mm) 8 3.6 10 4.5 10 4.5 21 9.5 23 10.4 23 10.4 22.2 10.1 24.2 11.0 24.2 11.0
1 in. (25 mm) 12 5.4 14 6.4 16 7.3 25 11.3 27 12.2 29 13.2 26.2 11.9 28.2 12.8 30.2 13.7
1½ in. (40 mm) 25 11.3 31 14.1 33 15.0 38 17.2 44 20.0 46 20.9 39.2 17.8 45.2 20.5 47.2 21.4