Graphical support mode The graphical support mode is called via the Device menu. Thus offers an alternative
method of configuring the Micropilot. Various pictures are offered when the Graphics
menu is clicked. These correspond to the procedures described in Chapter 6.
Status: software version, measuring point tag, diagnosis code and measured
value are displayed.
Commissioning: reset, measuring point tag, etc.
Basic calibration for tank: procedure for basic calibration in tanks.
Basic calibration for stilling wells: procedure for basic calibration in stilling wells.
Basic calibration Step 2: procedure for false echo suppression.
Technical units: settings for linear relationships.
Safety parameters: configuration of the analogue output for normal and failure
operation.
Service: parameters required for service call.
A linearisation can be called from the matrix window.
Off-line operation Commuwin also allows the Micropilot to be configured off-line. After all parameters have
been entered, the file generated can be loaded into the connected Micropilot. This can
now be commissioned by simply running the echo suppression procedure.
Up-/Download This function allows the parameters of an already configured Micropilot FMR 231 to be
loaded and stored in Commuwin II. If several Micropilots (with the same software version)
have to be configured in the same way, the parameters can now be downloaded into the
devices. In this case as well, an echo suppression must be made when the devices are
commissioned.
It is not possible to up and download parameters between Micropilots with different
software versions.
Graphical support - Basic calibration -Step 1-
EMPTY CALIBRATION
2.
3.50
FULL CALIBRATION
3.
3.00
APPLICATION
LOCK MATRIX
4.
1.* Code "333" Code >< "333"
4.* "0": Tank...approx. 7 m
"1": Tank...approx. 1.5 m
"2": Tank...approx. 7 m, DC<10
"3": Tank 7 m... 20 m
1.
1
333
3
2
100%
20mA
0%
4mA
BA171E32
Abb. 4.5
Graphic support window in
Commuwin II
Chapter 4 Operation Micropilot FMR 231
20 Endress+Hauser