EasyManua.ls Logo

Endress+Hauser Levelflex FMP54 - Page 35

Endress+Hauser Levelflex FMP54
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus Mounting
Endress+Hauser 35
Securing rod probes
For WHG approvals: For probe lengths ≥ 3 m (10 ft) a support is required.
In general, rod probes must be supported if there is a horizontal flow (e.g. from an
agitator) or in the case of strong vibrations.
Rod probes may only be supported at the end of the probe.
mm (in)
ø a
ø b
»50 (1.97)
1
2
3
»50 (1.97)
4
5
6
ø<25 (1.0)
3 (0.12)»
A0012607
1 Probe rod, uncoated
2 Sleeve bored tight to ensure electrical contact between the rod and sleeve!
3 Short metal pipe, e.g. welded in place
4 Probe rod, coated
5 Plastic sleeve, e.g. PTFE, PEEK or PPS
6 Short metal pipe, e.g. welded in place
 probe  a [mm (inch)]  b [mm (inch)]
8 mm (1/3") < 14 (0.55) 8.5 (0.34)
12 mm (1/2") < 20 (0.78) 12.5 (0.52)
16 mm (0.63in) < 26 (1.02) 16.5 (0.65)
NOTICE
Poor grounding of the end of probe may cause measuring errors.
Apply a narrow sleeve which has good electrical contact to the probe.
NOTICE
Welding may damage the main electronics module.
Before welding: Ground the probe and dismount electronics.

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP54

Related product manuals