Integration into a FOUNDATION Fieldbus network Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
92 Endress+Hauser
Name Label Index Data type Size (Bytes) Storage Class Write
access
MODE_BLK
sens_temp_status Status 67 ENUM8 1 Dynamic
eop_shift_status Status 70 ENUM8 1 Dynamic
terminal_voltage_1 Terminal voltage 1 97 FLOAT 4 Dynamic
calculated_dc_value Calculated DC value 100 FLOAT 4 Dynamic x AUTO
upper_interface_thickness Upper interface thickness 103 FLOAT 4 Dynamic
debug_value Debug value 106 FLOAT 4 Dynamic x AUTO
sw_option_active_overview SW option active overview 111 BIT_ENUM32 4 Static
locking_status Locking status 113 BIT_ENUM16 2 Dynamic
decimal_places_menu_ro Decimal places menu 109 ENUM16 2 Static x AUTO
linearization_type Linearization type 104 ENUM16 2 Static x OOS
eop_level_evaluation EOP level evaluation 112 ENUM16 2 Static x OOS
access_status_tooling Access status tooling 114 ENUM16 2 Static
calculated_dc_status Status 99 UINT8 1 Dynamic
status_up_iface_thickness Customized upper phase thickness
status
102 UINT8 1 Dynamic
debug_status 107 UINT8 1 Dynamic x AUTO
9.6.7 Service Sensor Transducer Block
The parameters of the Service Sensor Transducer Block can only be operated by
authorized Endress+Hauser service personnel.
9.6.8 Service Information Transducer Block
The parameters of the Service Information Transducer Block can only be operated by
authorized Endress+Hauser service personnel.
9.6.9 Data Transfer Transducer Block
The parameters of the Data Transfer Transducer Block are described in GP01015F:
"Levelflex FMP5x - Description of Device Parameters - FOUNDATION Fieldbus"
Name Label Index Data type Size (Bytes) Storage Class Write access MODE_BLK
used_calculation Used calculation 87 ENUM16 2 Dynamic
bdt_cfg_rdwr_ctrl 101 UINT16 2 Static x AUTO
bdt_transferred_ctrl 102 BYTEARRAY Static x AUTO
bdt_data_trans 103 BYTEARRAY Static x AUTO
bdt_prepare 99 BYTEARRAY Static x AUTO
bdt_status 100 BYTEARRAY Static
sw_option_active_overview SW option active overview 98 BIT_ENUM32 4 Static
digits_at_0_mVdB 90 FLOAT 4 Dynamic x AUTO
digits_per_mVdB 91 FLOAT 4 Dynamic x AUTO
actual_diagnostics Actual diagnostics 97 UINT32 4 Static
electric_probe_length Electric probe length 92 FLOAT 4 Dynamic
empty_calibration_ro Empty calibration 93 FLOAT 4 Static x OOS
full_calibration_ro Full calibration 94 FLOAT 4 Static x OOS