Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus Mounting
Endress+Hauser 45
Vessels with heat insulation
If process temperatures are high, the device must be included in normal tank
insulation to prevent the electronics heating up as a result of heat radiation or
convection. The insulation may not exceed beyond the points labeled "MAX" in the
drawings.
MAX
1
3
MAX
2
A0014653
 7 Process connection with thread - FMP51
1 Tank insulation
2 Compact device
3 Sensor remote (feature 600)
40(1.57)
40(1.57)
MAX
mm(in)
MAX
1
3
2
A0014654
 8 Process connection with flange - FMP51, FMP52
1 Tank insulation
2 Compact device
3 Sensor remote (feature 600)