What to do if Endress+Hauser Liquiline CM44P module connection fails?
- KKevin RodriguezSep 8, 2025
If the electronics module in your Endress+Hauser Controller is not communicating, check the module and replace it if necessary.

What to do if Endress+Hauser Liquiline CM44P module connection fails?
If the electronics module in your Endress+Hauser Controller is not communicating, check the module and replace it if necessary.
How to resolve high electronics temperature in Endress+Hauser Controller?
If your Endress+Hauser Controller reports a high electronics temperature, check the ambient temperature and energy consumption.
How to troubleshoot power consumption issues on Endress+Hauser Controller?
If your Endress+Hauser Controller has total power consumption too high, check the installation and remove sensors/modules.
What causes internal voltage issues in Endress+Hauser Controller?
If the internal voltage of your Endress+Hauser Controller is outside the valid range, check the supply voltage and check inputs and outputs for short-circuiting.
What causes sensor communication blocked in Endress+Hauser Liquiline CM44P?
If sensor communication is blocked on your Endress+Hauser Controller because the sensor fails tag check, replace it.
How to fix no communication with the actuator module in Endress+Hauser Controller?
Check the internal connecting cable to the 1IF module.
| Brand | Endress+Hauser |
|---|---|
| Model | Liquiline CM44P |
| Category | Controller |
| Language | English |
Defines the device's intended applications in non-hazardous and hazardous environments.
Lists different sensor types and their connection methods.
Details connecting modules for inputs, outputs, and relays, emphasizing shock protection.
Lists critical checks after connection to ensure safety and proper operation.
Covers communication via HART, PROFIBUS DP, Modbus, and Ethernet/IP protocols.
Covers making essential basic settings like device tag, date, and time for initial setup.
Explains input configurations for various sensors, including photometers and Memosens.
Covers configuration of current outputs and relay outputs for controlling external devices.
Lists hardware options enabling binary inputs/outputs and provides application examples.
Covers additional functions like limit switches, time switches, controllers, cleaning programs, and mathematical functions.
Provides a general approach to troubleshooting, including using diagnostic messages and contacting support.
Explains how to perform device tests, check power supply, and export results.
Details how to restart the device or reset it to factory default settings.
Provides instructions for cleaning the device, including permitted and prohibited cleaning agents.
Explains how to clean digital sensors and replace them, ensuring measuring point availability.
Lists spare parts with item numbers and order numbers, referencing an illustration.
Details various sensor types, including photometer, glass, ORP, ISFET, conductivity, and oxygen sensors.
Details input specifications for photometer and Memosens sensors, including measuring ranges, types, and signal characteristics.
Covers output signals, including analog and HART communication, and protocol-specific data.
Lists protocol-specific data for HART, PROFIBUS DP, Modbus RS485, Modbus TCP, EtherNet/IP, and PROFINET.