Micropilot FMR60B PROFINET with Ethernet-APL
Endress+Hauser 47
Drip-off antenna 50 mm (2 in), UNI flange process connection
A
B
1
1
R
L3
L2
!42.5 (1.67)
L4
L1
78 (3.07)
A0046480
 52 Dimensions of Drip-off antenna 50 mm (2 in), UNI flange process connection. Unit of
measurement mm (in)
A Process temperature version ≤150 °C (302 °F)
B Process temperature version ≤200 °C (392 °F)
1 Bottom edge of housing
R Reference point of measurement
L1 175 mm (6.89 in); version with Ex d or XP approval +5 mm (+0.20 in)
L2 77 mm (3.03 in); version with Ex d or XP approval +5 mm (+0.20 in)
L3 89 mm (3.50 in); version with Ex d or XP approval +5 mm (+0.20 in)
L4 187 mm (7.36 in); version with Ex d or XP approval +5 mm (+0.20 in)
UNI flange 3"/DN80/80A
G 1 1/2
20 (0.79)
!
200 (7.9)
!
150 (5.9)
!
160 (6.3)
45°
19 (0.75)
A0048847
 53 Dimensions of UNI flange 3"/DN80/80A. Unit of measurement mm (in)
Suitable for ASME B16.5, 3" 150lbs / EN1092-1; DN80 PN16 / JIS B2220; 10K 80A
Material:
PP, weight 0.50 kg (1.10 lb)