100
PARAM
Instrument data
System
configuration
Parameter
Calibration
Limit contactor
ATC cal. solution Calibration temperature
(for MTC)
Limit contactor 1
Limit contactor 2
Off
On
Meas. range 1-4
Current output
Error current
off
MIN current
MAX current
Output damping
Current output 2
Output damping
Current output 1
Hold type
fixed current value
lat measured value
Select characteristic
linear
linear, bilinear,
log. table
Select characteristic
linear
linear, bilinear,
log. table
Temperature coeff.
Tc
Hold current
(only for fixed
current value)
Current monitoring
(cable break monitoring)
active
inactive
Meas. current range
Current output 2
0 ... 20 mA
4 ... 20 mA
Meas. current range
Current output 1
0 ... 20 mA
4 ... 20 mA
2nd current output
(only for difference)
General settings
Current output 2
Current output 1
Limit configuration
Hold for calibration
no
yes
Limit contactor 1
Limit contactor 2
Operating mode
Auto
Manual
Limit contact
off/on
Select alarm
Meas. range
dependent
Meas. range
independent
Alarm configuration
Operating mode
Meas. range 1-4 Alarm threshold
Internal MRS
Short operation
Hold on
Hold off
Hold
Limit operating
mode
Setpoints
No. of MRs
no switch point 1
2 switch points 2
4 switch points 3
MR value threshold 1
(not for 1)
MR value threshold 2
(not for 1)
MR value threshold 3
(not for 1+2)
MR value threshold 4
(not for 1+2)
Temperature
Select meas. range
(only with FBU)
Type of Tc
no comp.
linear
NaCl DIN 746
Tc curve
Ultrapure water NaCL
Ultrapure water User
Temperature
measurement
Temperature
compensation
Temperature
manual (MTC)
automatic (ATC)
for Tc curve
(ATC)
set offset
Temperature
actual value 1
(ATC)
Set offset
Temperature
actual value 2
(ATC)
Display temperature
offset
Select substance
Substance name
Support points
Tc curve
Substance table
(MTC)
Temperature 2
(only for difference)
Ref. temperature
(MTC)
Temperature 1
for linear
Date TimeFilter length
Allign faults
to maintenance
contact
to no contact
NAMUR contact type
NC contact
NO contact
Contact type failure
relay
Fleeting contact
Steady contact
Language
Deutsch, English,
Francais, Italiano
Rerlay function
(dep. on configuration)
Measuring cell
CLS 50, CLS 52,
2-ring: k = 0,01;
k = 0,1; k = 1; k = 10
Measuring type
Conductivity
Concentration
Resistance
Temperature sensor 1
PT 100
PT 1000
NTC 30 kW
Measuring principle
1-circuit
Difference
(only difference)
Unit
Specialist codeRepair code
Meas. range 1-4
(only for FBU)
Select substance
No. of support points
Substance
Select substance Substance name
(for non-preprog.
substance)
Output contacts
Code
General settings
Temperature unit
°C, °F, K
Min/Max
function
Meas. range 1-4
Meas. range
dependent
Limit contactor 1
Limit contactor 2
Operating mode
Auto
Manual
Limit contact
off/on
Meas. range
independent
Limit 1 Meas. range 1-4 Limit 2Meas. range 1-4
Start-up
Language
Deutsch, English,
Francais, Italiano
Chemoclean
Dispaly contrast
Automatic in
Automatic off
Start cleaning
Date SI unit
mS/cm, mS/cm
mS/m, S/m
Measuring principle
(only for difference)
Measuring type
Conductivity
Concentration
Resistance (MW)
Time
Alarm delay
Automatic on
Automatic off
Setting
Chemoclean
Hysteresis
On delay
Hysteresis
USP

Table of Contents

Other manuals for Endress+Hauser Mycom CLM 152

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Mycom CLM 152 and is the answer not in the manual?

Endress+Hauser Mycom CLM 152 Specifications

General IconGeneral
BrandEndress+Hauser
ModelMycom CLM 152
CategoryTransmitter
LanguageEnglish

Related product manuals