10 Technical data PROline Promag 50
146 Endress+Hauser
Process connections with gasket seal (DN 40…100)
Weld nipples for DIN
1.4404 / 316L
5*H**-U***********
Sensor
DN [mm]
Fits to
Piping DIN 11850
di
[mm]
G
[mm]
D
[mm]
L
[mm]
L1
[mm]
LK
[mm]
40 42 x 2 38.0 43 92 42 19 71.0
50 54 x 2 50.0 55 105 42 19 83.5
65 70 x 2 66.0 72 121 42 21 100.0
80 85 x 2 81.0 87 147 42 24 121.0
100 104 x 2 100.0 106 168 42 24 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
LK
D
G
di
L1
L
F06-xxHxxxxx-06-09-07-xx-002
Weld nipples for ODT
1.4404 / 316L
5*H**-V***********
Sensor
DN [mm]
Fits to
Piping OD
di
[mm]
G
[mm]
D
[mm]
L
[mm]
L1
[mm]
LK
[mm]
40 38.1 x 1.65 35.3 40 92 42 19 71.0
50 50.8 x 1.65 48.1 55 105 42 19 83.5
65 63.5 x 1.65 59.9 66 121 42 21 100.0
80 76.2 x 1.65 72.6 79 147 42 24 121.0
100 101.6 x 1.65 97.5 104 168 42 24 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
LK
D
G
di
L1
L
F06-xxHxxxxx-06-09-07-xx-002
Clamp ISO 2852
1.4404 / 316L
5*H**-W***********
Sensor
DN [mm]
Fits to
Piping ISO 2037 /
BS 4825-1
Clamp ISO 2852
Diameter
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 38.0 x 1.6 38.0 35.6 50.5 92 68.5 71.0
50 51.0 x 1.6 51.0 48.6 64.0 105 68.5 83.5
65 63.5 x 1.6 63.5 60.3 77.5 121 68.5 100.0
80 76.1 x 1.6 76.1 72.9 91.0 147 68.5 121.0
100 101.6 x 2.0 101.6 97.6 119.0 168 68.5 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
G
di
LK
D
L
F06-xxHxxxxx-06-09-07-xx-005
Clamp DIN 32676
1.4404 / 316L
5*H**-0***********
Sensor
DN [mm]
Fits to
Piping DIN 11850
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 42 x 2 3850.59261.571.0
50 54 x 2 50 64.0 105 61.5 83.5
65 70 x 2 66 91.0 121 68.0 100.0
80 85 x 2 81 106.0 147 68.0 121.0
100 104 x 2 100 119.0 168 68.0 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
G
di
LK
D
L
F06-xxHxxxxx-06-09-07-xx-008

Table of Contents