PROline Promag 50 10 Technical data
Endress+Hauser 147
Tri-Clamp L14 AM7
1.4404 / 316L
5*H**-1***********
Sensor Fits to di G D L LK
DN [mm] DN [inch] Piping OD [mm] [mm] [mm] [mm] [mm]
40 1 1/2" 38.1 x 1.65 34.8 50.4 92 68.6 71.0
50 2" 50.8 x 1.65 47.5 63.9 105 68.6 83.5
65
63.5 x 1.65 60.2 77.4 121 68.6 100.0
80 3" 76.2 x 1.65 72.9 90.9 147 68.6 121.0
100 4" 101.6 x 1.65 97.4 118.9 168 68.6 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
G
di
LK
D
L
F06-xxHxxxxx-06-09-07-xx-004
Coupling:
Threaded adapter SC DIN 11851
1.4404 / 316L
5*H**-2***********
Sensor
DN [mm]
Fits to
Piping DIN 11850
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 42 x 2 38 Rd 65 x 1/6" 92 72 71.0
50 54 x 2 50 Rd 78 x 1/6" 105 74 83.5
65 70 x 2 66 Rd 95 x 1/6" 121 78 100.0
80 85 x 2 81 Rd 110 x 1/4" 147 83 121.0
100 104 x 2 100 Rd 130 x 1/4" 168 92 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
L
G
di
D
LK
F06-xxHxxxxx-06-09-07-xx-001
Coupling: Threaded adapter
DIN 11864-1, Form A
1.4404 / 316L
5*H**-3***********
Sensor
DN [mm]
Fits to
Piping DIN 11850
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 42 x 2 38 Rd 65 x 1/6" 92 71 71.0
50 54 x 2 50 Rd 78 x 1/6" 105 71 83.5
65 70 x 2 66 Rd 95 x 1/6" 121 76 100.0
80 85 x 2 81 Rd 110 x 1/4" 147 82 121.0
100 104 x 2 100 Rd 130 x 1/4" 168 90 141.5
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
L
G
di
D
LK
F06-xxHxxxxx-06-09-07-xx-006
Flange: Aseptic flat flange
DIN 11864-2, Form A
1.4404/316L
5*H**-4***********
Sensor
DN [mm]
Fits to
Piping DIN 11850
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK1
[mm]
LK2
[mm]
40 42 x 2 38 82 92 64 71.0 65
50 54 x 2 50 94 105 64 83.5 77
65 70 x 2 66 113 121 64 100.0 95
80 85 x 2 81 133 147 98 121.0 112
100 104 x 2 100 159 168 98 141.5 137
Fitting length = (2 x L) + 140 mm (DN 40…65) / + 200 mm (DN 80…100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 135)
and process connection (di) into account.
L
G
di
D
LK 1
LK 2
F06-xxHxxxxx-06-09-07-xx-007