Proline Promag W 800 Electrical connection
Endress+Hauser 35
7.2.3 Connecting the connecting cable in the remote version
1. Open the housing cover.
Release the four screws with a Phillips head screwdriver.
Lift the housing cover slightly and tip it to the left.
Two flexible fasteners secure the housing cover to the housing.
2. Push the cable through the cable entry 32.
To ensure tight sealing, do not remove the sealing ring from the cable entry.
3. Strip the cable ends and fit wire end ferrules 29.
4. Connect the cables in accordance with the terminal assignment. When connecting the
cable shield to the ground terminal, observe the grounding concept of the facility.
A0017027
Fig. 21: Connecting the remote version
1 Transmitter terminals
2 Sensor terminals
3 Coil current cable
4 Electrode cable
5. Fit the cable anchorage, firmly tighten the cable glands and secure the housing cover
again.
1
2
3
4
17
16 15 14
10
987 65
13
12 11
4 321
5 743742 41
Sensor Transmitter
Terminal Connection Terminal Connection
5 Electrode E1 (brown) 1 Electrode E1 (brown)
7 Electrode E2 (white) 2 Electrode E2 (white)
4
Reference electrode,
Terminals bridged (green)
3 Shield, electrode E1 (brown)
37 4 Shield, electrode E2 (white)
41 Coil current cable B2 (black) 11 Reference electrode (green)
42 Coil current cable B1 (black) 12 Coil current cable B2 (black)
13 Coil current cable B1 (black)