3 Installation PROline Promass 80
22 Endress+Hauser
3.3.3 Turning the local display
1. Remove the cover of the electronics compartment.
2. Press the side latches on the display module and remove it from the electronics
compartment cover plate.
3. Rotate the display to the desired position (max. 4 x 45° in each direction), and reset
it into the electronics compartment cover plate.
4. Screw the cover of the electronics compartment firmly onto the transmitter housing.
Fig. 12: Turning the local display (field housing)
3.4 Post installation check
Perform the following checks after installing the measuring device in the pipe:
Device condition and specifications Notes
Is the device damaged (visual inspection)?
−
Does the device correspond to specifications at the measuring point,
including process temperature and pressure, ambient temperature,
measuring range, etc.?
see Page 81 ff.
Installation Notes
Does the arrow on the sensor nameplate match the direction of flow
through the pipe?
−
Are the measuring point number and labeling correct (visual
inspection)?
–
Is the orientation chosen for the sensor correct, in other words suitable
for sensor type, fluid properties (outgassing, with entrained solids)
and fluid temperature?
see Page 14 ff.
Process environment / process conditions Notes
Is the measuring device protected against moisture and direct
sunlight?
−
F06-xxxxxxxx-07-xx-06-xx-000