Proline Prosonic Flow 91 Description of device functions
Endress+Hauser 81
SWITCH-OFF POINT
!
Note!
This function is not available unless LIMIT VALUE was selected in the ASSIGN STATUS
OUTPUT function.
Use this function to assign a value to the switch-off point (status output drops off).
The value can be equal to, greater than or less than the switch-on point.
Positive and negative values are permissible.
User input:
5-digit floating-point number, [unit]
Factory setting:
0 [unit]
!
Note!
The appropriate unit is taken from the SYSTEM UNITS group.
If SYMMETRY is selected in the MEASURING MODE function and values with
different signs are entered for the switch-on and switch-off points, the notice message
"INPUT RANGE EXCEEDED" appears.
Functional description PULSE/STATUS OUTPUT