Proline t-mass 65 PROFIBUS DP/PA Technical data
Endress+Hauser 115
Pressure measuring device
approval
The measuring devices can be ordered with or without PED (Pressure Equipment Directive). If a
device with PED is required, this must be ordered explicitly. For devices with nominal diameters
less than or equal to DN 25 (1"), this is neither possible nor necessary.
With the identification PED/G1/III on the sensor nameplate, Endress+Hauser confirms
conformity with the "Basic safety requirements" of Appendix I of the Pressure Equipment
Directive 97/23/EC.
Devices with this identification (with PED) are suitable for the following types of fluid:
Fluids of Group 1 and 2 with a steam pressure of greater or less than 0.5 bar (7.3 psi)
Unstable gases
Devices without this identification (without PED) are designed and manufactured according to
good engineering practice. They correspond to the requirements of Art. 3, Section 3 of the
Pressure Equipment Directive 97/23/EC. Their application is illustrated in Diagrams 6 to 9 in
Appendix II of the Pressure Equipment Directive 97/23/EC.
Oxygen service We certify that the wetted parts of the flow sensor have been degreased in accordance with British
Oxygen Company (BOC) specification 0000-N-S-430-00-01 and BS IEC 60877:1999.
After final degreasing there shall be less than 100 milligram/m² (0.01 milligram/cm²) of oil/grease
contamination on the degreased surface of the component.
Other standards and
guidelines
BS IEC 60877:1999
Procedures for ensuring the cleanliness of industrial-process measurement and control equipment
in oxygen service.
EN 60529
Degrees of protection by housing (IP code)
EN 61010-1
Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory
Procedures.
IEC/EN 61326
"Emission in accordance with requirements for Class A". Electromagnetic compatibility (EMC-
requirements).
EN 91/155/EEC
Saftey Data Sheets Directive.
ISO/IEC 17025
General requirements for the competence of testing and calibration laboratories.
ISO 14511
Measurement of fluid flow in closed conduits - Thermal mass flowmeters.
NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
NAMUR NE 43
Standardisation of the signal level for the breakdown information of digital transmitters with
analogue output signal.
NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics