Identification Smartec S CLD132
8 Endress+Hauser
2.1.3 Basic version and function extensions
2.2 Scope of delivery
The scope of delivery of the compact version inlcudes:
• Smartec S CLD132 compact measuring system with integrated sensor
• Terminal strip set
• Expansion bellows (-*GE1***** versions only)
• Operating Instructions BA 207C/07/en
• Versions with HART communication only:
Operating Instructions Field communication with HART, BA 212C/07/en
• Versions with PROFIBUS interface only:
– Operating Instructions Field communication with PROFIBUS, BA 213C/07/en
– M12 connector (-******PF* versions only)
The scope of delivery of the separate version includes:
• Smartec S CLD132 transmitter
• CLS52 inductive sensor with fixed cable
• Terminal strip set
• Expansion bellows (-*GE1***** versions only)
• Operating Instructions BA 207C/07/en
• Versions with HART communication only:
Operating Instructions Field communication with HART, BA 212C/07/en
• Versions with PROFIBUS interface only:
– Operating Instructions Field communication with PROFIBUS, BA 213C/07/en
– M12 connector (-******PF* versions only)
2.3 Certificates and approvals
Declaration of conformity
The product meets the legal requirements of the harmonised European standards.
The manufacturer confirms compliance with the standards by affixing the 4 symbol.
Functions of the basic version Options and their functions
•Measurement
• Calibration of cell constant
• Calibration of residual coupling
• Calibration of installation factor
• Read instrument parameters
• Linear current output
• Current output simulation
•Service functions
• Temperature compensation selectable (e.g. 1 free
coefficient table)
• Concentration measurement selectable (4 defined
curves, 1 free table)
• Relay as alarm contact
• Second current output for temperature (hardware
option)
• HART communication
• PROFIBUS communication
Remote parameter set switching (software option):
• Remote switching of max. 4 parameter sets
(measuring ranges)
• Temperature coefficients can be determined
• Temperature compensation selectable (e.g. 4 free
coefficient tables)
• Concentration measurement selectable (4 defined
curves, 4 free tables)
• Check of measuring system by PCS alarm (live check)
• Relay can be configured as alarm or limit contact