NS 5.14 Firmware
322 4900002262 rev. B 3-23-21
Common Weight: Ratio of the measured spectrum that did not
match a reference spectrum.
Concentration: Current measured (live) analyte concentration
(process or validation) in selected engineering units.
Concentration (ppmv): Current measured (live) analyte
concentration (process or validation) in parts per million by volume
(ppmv).
Concentration Process: Measured analyte concentration of last
process reading in selected engineering units.
Concentration Unit: Designates the display units for the measured
concentration.
Conc Process ppmv: Measured analyte concentration of last
process reading in parts per million by volume (ppmv).
Conversion Type: Sets the type of relations (ideal or real gas) used
in the dew point calculation [0 for ideal gas relations or 1 for real gas
relations (
Z calculated using Peng-Robinson EOS)].
Cross Shift: The amount shift applied to match the measured
spectrum to the reference spectrum when using Cross Correlation.
Current 2F Flag: Displays the current scrubber protection usage
level: 0 = standard protection (used for non-differential units), 1 =
mid protection, 2 = high protection, 3 = maximum protection (no
usage).
Current Midpoint: Current midpoint that the analyzer is using,
including any peak tracking adjustments.
Custom Precision: Sets the number of viewable digits to the right
of the decimal point.
Daily Validation: Enables or disables the time of day autovalidation
feature.
DC Level: Signal level at the high end of the current ramp.
Dew Point: Measured analyte concentration of last process reading
as a moisture dew point.
Dew Point Method: Sets the industry standard method with which
the dew point temperature is determined when Calculate Dew
Point is enabled.
DO Alarm Setup: Bitwise value that sets the functionality of the
Assignable Alarm, as listed in Table 2–3 on page 2–22.
Dry DC Level: Signal level at the high end of the current ramp from
the last scrubber cycle.
Dry Pressure (mb): Measured pressure (0.0 for non-differential
units) of the gas sample from the last scrubber cycle in millibar (mb).

Table of Contents

Other manuals for Endress+Hauser SpectraSensors SS2100i-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser SpectraSensors SS2100i-1 and is the answer not in the manual?

Endress+Hauser SpectraSensors SS2100i-1 Specifications

General IconGeneral
BrandEndress+Hauser
ModelSpectraSensors SS2100i-1
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals