The following tables provide more detailed descriptions about the performed EMC tests:
Emission tests
according to the E/ECE Regulation No. 10, Revision 4 (2012)
Radiated disturbance emission
test
Test method E/ECE Reg. No. 10, Annexes 7 and 8,
CISPR 25
Frequency (MHz)
Limit value (dBmV/m)
30 1000
62/52/63
(Broadband QP)
30 1000
52/42/53
(Narrowband AVE)
Conducted disturbances
emission test
Test method E/ECE Reg. No. 10, Annex 10, ISO
7637-2: 2004/Amd.1:2008
Port
Limit level (V)
12 V DC input
+75
-100
24 V DC input
+150
- 450

Table of Contents