Technical Manual &
Cabling Instructions
Page 45 / MAN000596
Approvals and Safety
Epec Oy reserves all rights for improvements without prior notice
Epec Oy
Tiedekatu 6
FIN-60320 Seinäjoki
Postal address
PL/P.O.Box 194
FIN-60101 Seinäjoki,
Finland
Phone
+358-(0)20-7608 111
Fax
+358-(0)20-7608 110
Internet
www.epec.fi
s according to the E/ECE Regulation No. 10, Revision 4 (2012)
Immunity to transient
disturbances conducted along
supply lines test
• Test method E/ECE Reg. No. 10, Annex 10, ISO
7637-2: 2004/Amd.1:2008
• Performance criterion:
2a A
2b C
3a A
4 C (12 V)
A (24 V)
• 12 V input, Pulse:
i
2a +112 V, R
i
2 Ω, 200 ms, 5000 pulses
2b +10 V, 500 ms, 10 pulses
3a -220 V, 10/90 ms, 60 min
4 t
d
25 ms -6,0 V, 5 s -2,5 V, 10 pulses
5a t
d
400 ms, R
i
0,5 Ω, +70 V, 1 pulse
d
i
• 24 V input, Pulse:
i
2a +112 V, R
i
2 Ω, 200 ms, 5000 pulses
2b +20 V, 500 ms, 10 pulses
3a -300 V, 10/90 ms, 60 min
3b +290 V, 10/90 ms, 60 min
4 t
d
100 ms -12 V, 20 s -5 V, 1 pulse
5a t
d
350 ms, R
i
4 Ω, +123 V, 1 pulse
d
i