191
Automatic light source calibration may not start in the following conditions:
• Within 20 minutes of turning on the projector.
• When using direct power shutdown.
• When you have used the projector continuously for over 24 hours.
• When the brightness is automatically dimmed due to high temperatures.
• When the brightness is automatically dimmed due to use of the Dynamic Contrast, Lights-Out
Control, A/V Mute (EB-PU2113W/EB-PU2116W/EB-PU2120W), or Shutter
(EB-PU2213B/EB-PU2216B/EB-PU2220B) features.
• If Brightness Settings is set to 30% or less.
Note: To perform a light source calibration, the projector must have been on for at least 20 minutes and
the projector brightness must not be automatically dimmed due to high temperatures.
1. Press the Menu button.
2. Select the Reset menu and press Enter.
You see a screen like this:
3. Select Light Source Calibration and press Enter.
4. Select any of the following:
• To run the light source calibration now, select Run Now.