Setup & Operation 2. Specifications
S5 Rev.5 19
2.2 Model Number
S5 - A 701 S R - UL
UL specification
UL : UL compliant
: Non UL compliant
Type
: Table Top mounting
W : Wall mounting
R : Ceiling mounting
Environment
S : Standard model
C : Clean-room model
P : Protection-model
Arm length
7 : 706 mm (Model name: S5)
9 : 895 mm (Model name: S5L)
Environment
Cleanroom-model
Cleanroom-model Manipulator includes additional features that reduce dust emitted by
the Manipulator to enable use in clean room environments.
Cleanliness level : Class ISO 3 (ISO14644-1)
In previous criteria;
Clean Class: 10 or its equivalent. Amount of Dust (0.1 µm
diameter or larger) in 28317 cm
3
(1cft) sample-air around the
center of the motion rang: 10 particles or less.)
Exhaust System : Exhaust port diameter:
Inner diameter: ø12 mm / Outer diameter: ø16 mm
Exhaust tube : Polyurethane tube
Outer diameter: ø12 mm (Inner diameter:ø8 mm)
or Inner diameter ø16mm.
Recommended exhaust flow rate : Approx. 1000 cm
3
/s (Normal)
Protection-model (IP65)
The Protection-model Manipulators operate under adverse conditions with dust and oily
smoke.
IP (International Protection) for the Protection-model Manipulator indicates
International Standard of the protection level against dust and water.(IEC 60529, JIS
C0920)
Degree of protection
IP65
Dust : 6 No ingress of dust.
Water : 5
Water projected by a nozzle against enclosure from any direction
shall have no harmful effects.
For details on the specifications, refer to Setup & Operation: 2.4 Specifications.