Maintenance 6. Alarm
30 RC700 Series Maintenance Rev.3
6.1.3 How to Edit the Alarm Information
The configured alarm information can be edited in the EPSON RC+ 7.0.
(1) Select EPSON RC+ 7.0 menu-[Tools]-[Maintenance] to display the [Controller
Tools] dialog box.
(2) Select the alarm to be changed and click the <Change> button.
(3) Display the [Change Alarm] dialog box and enter any of the followings.
Purchase or replacement date of the battery
Date of grease up
(4) Click the <OK> button and change the specified alarm information.
6.1.4 Alarm Notifying Method
The alarm notifying method needs to be configured by the output bit of the Remote I/O.
The Remote I/O can be configured in the EPSON RC+ 7.0- [Setup] - [System
Configuration] - [Controller] - [Remote Control].
For details, refer to the EPSON RC+ 7.0 User’s Guide 12.1 Remote I/O.
The Controller does not enter the error or warning state even if an alarm occurs.
NOTE

Table of Contents

Other manuals for Epson RC700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700 Series and is the answer not in the manual?

Epson RC700 Series Specifications

General IconGeneral
ModelRC700 series
CategoryController
Programming LanguageSPEL+
Safety StandardISO 10218-1
TypeRobot Controller
Communication InterfaceEthernet, RS-232, USB
Operating Temperature0°C to 45°C (32°F to 113°F)
Humidity20% to 80% (non-condensing)
Number of controllable robots4