Maintenance 8. Maintenance Parts Replacement Procedures
RC700 Series Maintenance Rev.3 55
MDB
Installation
(1)
Install the MDB clamp 3.
(Mounting screw
×2)
(2)
Insert the MDBs in the direction shown in
the
picture.
Be careful not to misplace the
boards.
(3)
Install the MDB clamp 2.
(Mounting screw
×2)
Set the MDB clamp so that the
grooves fit
to MDBs.
(4)
Mount the MDB clamp 1.
(Mounting screw
×5)
(5)
Mount the output cable of each axis of
the MDBs.
When mounting the output cables, make sure that
the number
s on the MDB clamp 1 and on the
connector
s are the same.
(6
)
Mount
the Top Panel. (Mounting screw ×6)
(7
)
Connect
the power plug. Turn ON the Controller and make sure that the
Controller
starts properly without any vibration or abnormal noise.
NOTE
NOTE

Table of Contents

Other manuals for Epson RC700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700 Series and is the answer not in the manual?

Epson RC700 Series Specifications

General IconGeneral
ModelRC700 series
CategoryController
Programming LanguageSPEL+
Safety StandardISO 10218-1
TypeRobot Controller
Communication InterfaceEthernet, RS-232, USB
Operating Temperature0°C to 45°C (32°F to 113°F)
Humidity20% to 80% (non-condensing)
Number of controllable robots4

Related product manuals