4.2.6.5 P Thick1 Sensor, P Thick2 Sensor
1. Remove the H TOP COVER ASSY. See Section 4.2.3.2 on page 221.
2. Remove the screw that secures the P Thick Sensor Mounting Plate and remove it.
See Figure 4-93.
One C.C.S. M3 x 8 screw
3. Release the three tabs that secure each of the P Thick1 Sensor and the P Thick2
Sensor and remove the two Sensors. See Figure 4-94.
4. Remove the connector both from the P Thick1 Sensor and the P Thick2 Sensor.
See Figure 4-94.
Figure 4-93. Screws Securing the P Thick Sensor Mounting Plate
Figure 4-94. Removing the P Thick1 Sensor and P Thick2 Sensor
When reinstalling the P Thick Sensor Mounting Plate, make sure
the two guide pins on the Mounting Plate are set in the mounting
holes. See Figure 4-93.
A D J U S T M E N T
R E Q U I R E D
Whenever either or both of the P Thick1 Sensor and the P Thick2
Sensor is/are reinstalled or replaced, the corresponding adjustment
must be carried out. See Chapter 5 on page 292.
P Thick Sensor Mounting Plate
Guide Pins
Upper Right of the Printer
C.C.S. M3x8
P Thick1 Sensor
4
P Thick2 Sensor
4
3-1
3-2
3-2
3-1
3-1
3-1
3-1
3-1