163
LCD screen message Condition/solution
Cannot move the
movable base.
Check around the
movable base, and then
press [OK].
Check the following and then select OK:
• Remove anything that is on the platen that is not media.
• Make sure there are no wrinkles on the surface of the loaded media.
Reload the media so that it is flat.
• Check that the spacer combination and platen height (scale) are suitable
for the media you are using.
• Remove anything that has fallen around the movable base.
Failed to inspect the
condition of nozzles.
Cannot run "Auto
Cleaning".
Select cleaning strength
manually and run
Cleaning.
The printer has exceeded the temperature at which normal operation is
guaranteed. Adjust the temperature of the room and start again.
No reprint data found.
A memory device or
USB memory stick is
required to reprint.
See your documentation
for details.
You cannot reprint a print job unless a USB memory stick is connected to the
printer.
Cannot use the inserted
Memory Device.
For details, see your
documentation.
Check the following:
• The USB memory stick may be corrupt. Use a different USB memory stick.
• There is not enough free space on the USB memory stick or the maximum
number of readable files (999) has been exceeded. Delete any
unnecessary files or use a different USB memory stick.
• The USB memory stick was removed from the printer while data was being
written or read. Before removing the USB memory stick, make sure that
the light on the device is not flashing or on.