EasyManua.ls Logo

ERS AirCool plus - Chuck Cable Check

Default Icon
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ERS
®
Manual / AirCool
®
plus
-System / SP72_TA1C8 / -55°C +200°C / Ver. 02.02 48
11.1.3 Chuck cable check
Electrical connection between chuck TA1C8 and connector XR1 at the backpanel of
the controller SP72.
(see also fig. 5.1a)
Take the target resistance values from table 11.1.3b!
Fig. 11.1.3a Chuck power cable and extension cable
Warning
Disconnect the connector XC1 before resistance checking!
XR1
Connector
XC1
9
8
7
6
5
4
3
K
M
G
1
2
Extension cable
Power chuckcable
H
C
J
A
E
F
9
8
7
6
5
4
3
1
2
Chuck TA1C8
SP72
9pol.AMP
bushing housing
1
4
7
2
5
8
3
6
9
Pin load XC1
(side A resp. B
of both connectors)
A
B
C
D
EF
G
H
I
J
K
L
M
N
PinloadXR1
9yellow H
6brown C
8blue J
7pink A
5gray E
4 green F
2red K
1blue M
3 shielding G

Table of Contents