INSTALLATION AND CONNECTIONS
0740 801 028
- 19 -
© ESAB AB 2017
Travel limit switches
There are two inputs for limit switches.
At terminal block X1, remove link
between 11 and 12.
At terminal block X1, remove link
between 13 and 14.
Connect the first limit switch to terminal
block X1 at 11 and 12.
Connect the second limit switch to
terminal block X1 at 13 and 14.
Connection for limit switches
Motor drive and field supply
Power connection to motor 1 and 2
There are outputs to drive two motors. The motors are connected directly to the 26AP2 motor
drive board with an ESAB accessory cable.
Motor 1 for wire feed, connect to CN7.
Motor 2 for travel, connect to CN6.
At the back of the unit, remove the plug(s) from the hole(s).
Push the board connector(s) through the hole(s) and secure the strain relief(s).
Connect to the motordrive board 26AP1 at CN6 and/or CN7.