Step 7: Adjusting the electronic controller for gas type
Ensuring the gas is still OFF, Turn the power ON.
On the remote control, insert the new “AA” size batteries. You should now
see the time on the display showing 0:00
Press the MINUS (4), PLUS (8) and FAN BOOST (7) buttons simulta-
neously (as shown right) until the characters “03” light up on the display.
Release the buttons and the remote will count down and display “GO”. The
screen will then display all characters. This will put the remote into test
mode and the two big temperature digits should begin counting from 0 to 99
repeatedly.
Now hold down the “Edit Timer” button and “Activate Timer” button
simultaneously, the remote display will show the current configuration of
either “NG” for Natural or “LP” for ULPG/Propane. To change this configuration, hold down the same
2 buttons “Edit Timer” and “Activate Timer” simultaneously for 5 seconds. This will now have toggled
between gas types.
Once you are have chosen the correct gas mode, simply press the “ ” power button once to exit this
diagnostics mode.
E8 Operating the Appliance
Turn on the fire by pressing the “ ” power button the remote and within a few seconds the appliance
will begin its startup sequence, with a 15 second purge of the flue fan. After purge it will attempt igni-
tion. It may take a few attempts to light the first time due to air in the gas line. You may wish to purge
the gas line at the valve by bleeding the first test point. This requires a small blade screwdriver.
Once the fire has lit the pilot and main burner you will be able to measure the operating pressure. Set
the remote temperature to 40deg by pressing the “+” button and ensure the remote is kept in a cool
environment. This will allow maximum gas flow into the appliance.
Ensure all other gas appliances within the house are also operating at maximum.
If the operating pressure does not read within 5% of the table (shown on the next page) then remove
the cap from the gas pressure regulator within the appliance and adjust the threaded spring stop.
Press the “ ” power button again to shut down the fire.