Code Name Description Range
factory setting
P8.08 LCD screen color 0,1
0
0: White background (normal).
1: Black background (anti).
P8.09 LCD language 0,1
0
0: Chinese.
1: English.
P8.10 Reset Eshine special parameters 00
99
00
00: Invalid.
01: Reset the controller KS800 parameters.
02: Reset the controller KS900 parameters.
03: Reset the controller MS800 parameters.
04: Reset the controller MS900 parameters.
05: Reset the controller PL1100 parameters.
06: Reset the controller PL1200 parameters.
07-10: Reserved.
11: Reset the panel KS800 parameters.
12: Reset the panel KS900 parameters.
13: Reset the panel MS800 parameters.
14: Reset the panel MS900 parameters.
15: Reset the panel PL1100 parameters.
16: Reset the panel PL1200 parameters.
17-99: Reserved.
P8.11 CD door blade closed speed 0.00
2.00Hz
0.00Hz
It defines the door machine running speed (frequency) when the door blade acting position is in the
P8.12 setting range during CD process.
P8.12 CD door blade closed speed position 0
80
0
When the pulse number does not exceed the pulse nuber set by P8.12, the door machine will run at
the speed set by P8.11.
P8.13 Reserved
Synchronous motor initial start mode selection
0: Pulse location.
1: Current location.
2: Reserved.