SuZhou Eshine Elevator Components Co., Ltd. Appendix A Parameters
YS-K01 Door Controller User Manual -57-
Code Name Range KS MS Attributes Setting
Group P0 Basic Parameters (on pages 33
34)
P0.00 User password 00000-65535 0000 0000 ○
P0.01
disposal selection
00: No function. It need
manually set the parameter
01: Upload parameters
02: Download parameters
03: Reset default parameter,
synchronous motor
parameters
04: Clear fault information.
05-10: Reserved
11: Reset the first group
parameters of Eshine (reset
70W asynchronous motor
parameters)
12: Reset the second group
parameters of Eshine (reset
80W asynchronous motor
parameters)
13: Reset the third group
parameters of Eshine (reset
150W asynchronous motor
parameters)
14-30: Reserved
00 00 ×
P0.02
number
1-12 1 1 ×
P0.03
number
1-12 1 1 ×
P0.04
disposal comfirm
0: No function
1: Press key to comfirm
the batch disposal. This
parameter (P0.04) will restore
to zero when the parameter
batch disposal is finished
0 0 ×
P0.05 Mode selection
0: Factory mode (door
machine specific function is
invalid)
1: Door control mode
1 1 ×
P0.06
selection
0: Panel control
1: Terminal control (auto)
2: Auto-demo run
1 1 ×
P0.07
frequency
1.00-99.99Hz 24.00Hz 50.00Hz ×
P0.08 Advanced password
After input the advanced
password, you can check the
advanced parameters
0000 0000 ○
P0.09 Control mode
0: Asynchoronous motor
open-loop distance control
2 1 ×