EasyManua.ls Logo

EWM SATURN MIG 300 PROGRAM - Selection of Operating Modes; Choke Tappings; A - Meter with Hold - Function M110 (Option); Display Actual Values During and after Welding

EWM SATURN MIG 300 PROGRAM
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Steuerungsbeschreibung M100 / M110
5/2
5.1.2 Selection of Operating Modes
Operating mode
selection switch
The operating modes can be suited to the corresponding
welding job
2- Stroke Setting e.g.: Tacking, short weld seams (latch on, latch off)
4- Stroke Setting e.g.: long weld seams
Spot Welding Setting e.g.: Spot Welding
Interval Setting e.g.: Tack welding in chassis construction
5.1.3 Choke Tappings
Selection of Choke
Tapping 2 Choke Tappings are available for selection to suit the
shielding gas:
1
Choke Setting 1 "hard" welding choke setting
e.g. for welding with CO
2
2
Choke Setting 2 "soft" welding choke setting
e.g. for welding with Mixed gases Argon
5.2 V/A - Meter with Hold - Function M110 (Option)
5.2.1 Display of actual values during and after welding
The digital VA meter is available as an option for the M100 or M201 controls.
The welder is informed of the actual voltage and current values during welding with this display.
Further, the last welding data is stored on the screen (Hold- Function).

Table of Contents

Related product manuals