SIS Command and Response Table for Advanced Matrix Switcher Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Information requests
Information request
I
V
X4^
X
X4&
A
X4^
X
X4&]
V (video) matrix size•A (audio) matrix size
Request part number
N
60
-nnnn-nn
]
See the Extron Website for part numbers.
Request input/output board
configuration
*N
60
-nnnn-nn.
X4*
1
X4*
2
...
X4*
n
X4(
1
X4(
2
...
X4(
n
]
Part number, dot, 4, 8, or 16 (n)
X4*
s;
each is the input board installed, starting
from input slot 1, followed by 4, 8, or 16
(n)
X4(
s; each is the output board
installed.
NOTE: There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the
overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware
update, which is available at www.extron.com.
Query controller firmware version
Q
X5)]
Example:
Q
1.23
]
The factory-installed controller firmware
version is 1.23 (sample value only).
Query controller firmware version
(verbose)
0Q
X5)
-
X5!
-
X5!]
Detailed status of the controller firmware
and any firmware upgrade. The active
firmware is marked by an asterisk (*).
A caret (^) indicates a bad checksum
or an invalid load. ?.?? indicates that
firmware is not loaded.
Response description: Ethernet protocol firmware version-controller firmware version-updated firmware version
Example:
0q
See below
Ether
net protocol
firmware
Description
XTP CrossPoint firmware version Updated firmware version
* indicates the version running Upload date and time
1.23-1.00(1.06-XTP CP Series -Tue, 02 Dec 2010 00:00:00 GMT)-1.00*(1.06-XTP CP Series -Mon, 02 Apr 2012 16:39:21 GMT)
NOTE:
X4^
= Number of inputs 4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, or 64
X4&
= Number of outputs
4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, or 64
X4*
= Installed input board F = XTP CP 4i VGA N = XTP CP 4i Fiber 4K
G = XTP CP 4i (TP) P = XTP CP 4i 3G-SDI
H = XTP CP 4i HDMI S = XTP CP 4i HD 4K PLUS
I = XTP CP 4i DVI Pro X = No board installed
X4(
= Installed output board D = XTP CP 4o (TP) M = XTP CP 4o SA (stereo audio)
E = XTP CP 4o HDMI O = XTP CP 4o Fiber 4K
J = XTP CP 4o DVI Pro T = XTP CP 4o HD 4K PLUS X = No board installed
X5)
= Firmware version number to second decimal place (x.xx)
X5!
= Verbose firmware version-description-upload date/time (see the Query firmware version (verbose) command, above.
XTP II CrossPoint 1600, 3200, and 6400 Switchers • Programming Guide 114

Table of Contents

Other manuals for Extron electronics XTP II CrossPoint Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics XTP II CrossPoint Series and is the answer not in the manual?

Extron electronics XTP II CrossPoint Series Specifications

General IconGeneral
BrandExtron electronics
ModelXTP II CrossPoint Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals