Setting the Front Panel Locks (Executive Modes)
The matrix switcher has three levels of front panel security lock that limit the operation of the
switcher from the front panel. The three levels are:
• Lock mode 0 — The front panel is completely unlocked. All front panel functions are
available.
• Lock mode 1 — All changes are locked from the front panel (except for setting Lock
mode 2). Some functions can be viewed.
• Lock mode 2 — Basic functions are unlocked. Advanced features are locked and can
be viewed only.
Basic functions consist of:
• Making ties
• Saving and recalling presets
• Setting input audio gain and attenuation
• Changing Lock modes
Advanced functions consist of:
• Setting audio output mutes
• Setting audio output volume
• Setting the rear panel remote port protocol and baud rate
NOTE: The switcher is shipped from the factory in Lock mode 2.
Selecting Lock mode 2 or toggling between mode 2 and mode 0
NOTE: If the switcher is in Lock mode 0 or mode 1, this procedure selects mode 2. The
Preset, View, and Esc buttons blink twice.
If the switcher is in Lock mode 2, this procedure selects mode 0 (unlocks the switcher).
The View and Esc blink twice.
Toggle the lock on and off by pressing and holding the Preset button, the View button,
and the Esc button simultaneously for approximately 2 seconds (see figure 47).
C O N T R O L
ESCVIEW
PRESET
ENTER
C O N T R O L
ESCVIEW
PRESET
ENTER
C O N T R O L
ESCVIEW
PRESET
ENTER
C O N T R O L
ESCVIEW
PRESET
ENTER
Press and hold for
2 seconds.
Lock mode 2
Lock mode 0
Press and hold for
Figure 47. Toggle Front Panel Lock Between Mode 2 and Mode 0
XTP II CrossPoint 1600, 3200, and 6400 Switchers • Operation 62