EasyManuals Logo

Extron electronics XTP II CrossPoint Series User Manual

Extron electronics XTP II CrossPoint Series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Setting up SMTP authorization
If desired, set the XTP II CrossPoint to require SMTP authorization before accepting any
e-mail as follows:
1. Click Edit. The button changes to Save.
2. Check the SMTP Authorization Required check box, located below the Domain
Name field. This enables the User Name and Password fields below the check box.
3. Enter a user name and a password in the User Name and Password fields. For the
XTP II CrossPoint to accept their e-mail messages, senders must enter the user name
and password.
NOTES:
For the User name, any combination of letters, numerals, spaces, and symbols
except the comma (,) and the single and double quotation marks (‘ and “) are
valid. For the password, all characters except the comma are valid. The user
name and password can each be from 1 to 30 characters.
Both a user name and a password must be specified.
4. Click Save to save the user name and password.
Deselecting SMTP authorization
Remove SMTP authorization as follows:
1. Click Edit. The button changes to Save.
2. Click (deselect) the SMTP Authorization Required check box.
3. Click Save.
Domain Name field
The Domain Name field displays the domain name that the XTP II CrossPoint switcher uses
to log on to the e-mail server. Standard domain name conventions (for example: xxx.com)
apply.
NOTE: The HTML language reserves certain characters for specific functions (see
Special Characters on page 118). The @ character is acceptable only as the lead-in
to the domain name (such as @folklore.net).
Email Address fields
The five Email Address fields identify the e-mail addresses of the personnel to whom the
XTP II CrossPoint switcher e-mails notification of its failure and repair status. Standard e-mail
address conventions (nnnnn@xxx.com) apply.
The check boxes and drop boxes associated with each address field permit the operator
to specify specific criteria under which the switcher will e-mail recipients. In the associated
Missing Inputs scroll boxes, select the inputs to monitor for presence or absence of a
signal. Check the Fans and Power boxes to monitor the cooling and power supplies. In the
associated EMail Options drop-down list, select whether the recipient is to be e-mailed of
failures, fixes, both, not notified, or to be removed from the e-mail list. The Suspend option
is useful for temporarily removing personnel from the e-mail list when they are unavailable,
such as if travelling or on vacation. Deleting an e-mail addressee and clicking the Save
button removes the recipient from e-mail notification completely.
XTP II CrossPoint 1600, 3200, and 6400 Switchers • HTML Operation
129

Table of Contents

Other manuals for Extron electronics XTP II CrossPoint Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics XTP II CrossPoint Series and is the answer not in the manual?

Extron electronics XTP II CrossPoint Series Specifications

General IconGeneral
BrandExtron electronics
ModelXTP II CrossPoint Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals