6. ELECTRONIC INSTALLATION
RISKS
PERSONAL PROTECTIVE EQUIPMENT
F
ALWAYS DISCONNECT THE POWER SUPPLY before
working on the board. Turn power on only after
having made all the electrical connections and carried
out the preliminary start-up checks.
6.1 COMMUNICATION BOARD
Install the Communication board (§ 11), if used.
6.2 COVER
Replace the transparent cover.
6.3 CONNECTING TO THE MAINS POWER
SUPPLY
F
CARRY OUT THE FOLLOWING OPERATIONS WITH THE
ELECTRICITY SUPPLY DISCONNECTED.
With reference to 22:
- Connect the mains power cable to the terminals (1)
following the colour scheme indicated.
- Secure the power cable using the cable grip (2).
- Install the mains power terminal board cover (3)
and fasten it in place using the screw.
6.4 CONNECTING TO THE I/O BOARD
F
CARRY OUT THE FOLLOWING OPERATIONS WITH THE
ELECTRICITY SUPPLY DISCONNECTED.
1. Place the accessories connection cables in the
upper and lower guides and press the cable clips
(23).
2. Connect the wires to the terminal boards in 24.
The terminals are of the spring type: to insert or
remove the wires, press the button with the tip of
a screwdriver.