A951 61 532081 - RevA
A1
A2
S1 S2
56
57
A1 A2
S4
S3
S1
S2
A1
A2
S1 S4
S3S2
Translation of the original instructions
ENGLISH
A951
2 leaves
MASTER
ID=1
A951
2 leaves
SLAVE
ID=2
A951
Master interlock
2 leaves MASTER
ID=1
A951
Slave interlock
2 leaves MASTER
ID=3
A951
2 leaves
SLAVE
ID=2
A951
2 leaves
SLAVE
ID=4
INTERLOCK WITH MEMORY
With 2 sensors or buttons: the second opening is
automatic.
S1 S2
A1 closed A2 closed A1 opens, then
A2
A2 opens, then
A1
A1 NOT closed, A2 closed A1 opens and
request opening
of A2
request
opening of A2
A1 closed, A2 NOT closed request
opening of A1
A2 opens and
request opening
of A1
15.4 2 LEAVES + INTERLOCK
57 shows the IDs to assign to the A951 units in
the network.
This configuration integrates the
2 LEAVES function (on
two double-leaf accesses) with the interlock function.
Refer to the operating modes described above.
15.3 2 LEAVES
56 shows the IDs to assign to the A951 units in
the network.
If the two doors overlap, the one that opens first is
designated as the
Master. If there is no overlap, either
of the two units can be designated as the Master and
the other as the Slave.
The movement of the leaves 2 is synchronised.
The internal / external door sensors and safety devices
must be connected to their own unit; all other devices
are connected only to the Master.
Connect the devices and carry out the programming
and set-up on the individual A951 units before acti-
vating the
2 LEAVES function.
To change the operating mode, only use the
Master
A951.
The leaf opening / closing delay can be set in menu
2.5.5 of the KP EVO.
INTERLOCK WITH NO MEMORY
With 4 sensors: the second opening is not automatic.
In order to open the door, the internal/external sensor
must be triggered when the other door is closed. If the
sensor is activated while the door is not yet closed, it
has no effect.
S1 S2 S3 S4
A1 closed
A2 closed
A1 opens A1 opens A2 opens A2 opens
A1 NOT closed
A2 closed
A1 opens A1 opens request
opening
of A2
request
opening
of A2
A1 closed
A2 NOT closed
request
opening
A1
request
opening
A1
A2 opens A2 opens
EXTERNAL OPEN
EXTERNAL OPEN
EXTERNAL OPEN
EXTERNAL OPEN INTERNAL OPEN
INTERNAL OPEN