EasyManua.ls Logo

FAAC A951 - System Set-up and Programming; General Set-up and On-Board Programming

FAAC A951
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A951 32 532081 - RevA
29
Translation of the original instructions
ENGLISH
RISKS
PERSONAL PROTECTIVE EQUIPMENT
!
Before starting up the system, make sure that the door
moves smoothly and without friction.
1. Close the door.
2. Turn power on to the A951.
3. Check that the status of the LEDS on the I/O board
(§ 9.1) is correct.
4. Programming the A951 (§ 7.1).
!
Make sure you set the parameter relative to the type
of arm actually installed.
If the parameter is set incorrectly, the shaft of the
motor will rotate in the wrong direction and the door
will operate in the opposite way (door open when it
should be closed and vice versa).
5. Carry out the set-up procedure (§ 7.4).
6. Carry out the final operations (§ 14).
7.1 PROGRAMMING THE A951
There are two ways to program the A951:
- On the board, using the display and the integrated
buttons.
- Via the KP EVO.
The operating parameters for a typical installation
are available for the on board programming function.
Other functions are also available when programming
via the KP EVO, in addition to the on board program-
ming parameters.
7.2 ON BOARD PROGRAMMING
!
Before proceeding, make sure that the transparent
cover shown in 3-9 has been installed on the
door operator.
When power is turned on, the display of the A951
automatically adjusts to the direction in which the
door operator has been mounted. The 3 programming
buttons therefore assume different meanings.
Their meanings in the two mounting positions are
printed on the cover. The LEDs illuminate the sym-
bols or letters to use as shown in 29.
On board programming can be inhibited by using
parameter 2.7.2 of the KP EVO menu.
7. SETUP
Programming note:
- Changes made to the parameters are only saved
when you exit from the programming function.
- Programming is interrupted after 10 minutes if
buttons +,
-
and F have not been pressed. The
display returns to the automation status view and
any unsaved changes have to be re-entered.
- If there is a power failure during programming, any
unsaved changes have to be re-entered.
- Press F and - at any stage during programming to
exit from the programming function and save the
changes made.
- Programming using the KP EVO offers a larger num-
ber of functions or values compared to on board
programming. The board does not display any
values that are not available and indicates them
with EP (External Program).

Table of Contents