EasyManua.ls Logo

FAAC A951 - Basic Programming Function List

FAAC A951
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A951 34 532081 - RevA
Translation of the original instructions
ENGLISH
BASIC Programming Default
dS
PARTIAL STOP SEC.
Defines the detection area of the safety in opening
no = obstacle detection active over the entire opening
stroke.
Y= obstacle detection NOT active in proximity to the
opening stop
NO
!
Do not enable this function if users are children,
elderly, disabled or persons that are not steady on
their feet.
Enabling this function requires the set-up procedure
to be run with the device connected: the activation
of the device during opening determines the point
at which obstacle detection will be disabled during
normal operation.
St
EXIT PROGRAMMING
Exit from the programming function deciding whether
or not to save the changes
Y = save
no = do not save
After exit, the display shows automation status:
00 CLOSED
01 OPENING
02 OPEN
03 PAUSE
04 NIGHT PAUSE
05 CLOSING
06 EMER ACTIVATE
07 MANUAL
08 NIGHT
11 STOP
12 SECURITIES TEST
13 ERROR
LO-L2 SET-UP IN PROGRESS
9 BASIC Programming
BASIC Programming Default
dF
DEFAULT Configuration
Displayed if the board is configured with the factory
settings (default).
Y = the board is configured with the default settings
no = at least one value has been modified compared
to the default settings
If you wish to reload all the default settings, select
Y
and exit from programming
Y
t
ARM TYPE
1 = skid
2 = articulate
1
PG
PUSH & GO
Commands the automatic opening of the door after an
initial manual push
0 = disabled
1 = enabled
2 = enabled in FAST FOOD“mode (manual opening,
motorised closing)
0
PA
PAUSE TIME
Adjusts the pause time of the door when opened by a
command, before closing automatically.
Adjustable from 0 to 30 s
2
PP
PAUSE TIME P&G
Adjusts the door pause time when opened by a Push &
Go command,
before closing automatically
Adjustable from
0 to 30 s
2
Pn
NIGHT PAUSE TIME
Adjusts the door pause time when opened by a com-
mand in the NIGHT mode, before closing automatically
Adjustable from
0 to 90 s
10
CS
CLOSING SPEED
Adjustable from 1 (minimum) to 10 (MAX)
3
OS
OPENING SPEED
Adjustable from 1 (minimum) to 10 (MAX)
10
9

Table of Contents