EXTENDED MODE
CARD G / FIT 54 V 6.15 E / April 2010
ATTEMPTS
FACTORY SETTING: 2 x
The FIT-controller alarms the operator and prompts LOADING ALARM if a vacuum hopper loader fails to
fill the drying hopper after the number of attempts set in this parameter.
CLEANING
FACTORY SETTING: 2 x
Self contained vacuum loaders require filter cleaning before the suction process is started. Here the
operator can choose how many times the filter is cleaned.
CHANNEL A
FACTORY SETTING: 5.0s
This parameter can be set if two materials are conveyed and mixed.
Material A is drawn for this time period. The suction time for vacuum loaders is automatically corrected
by the program (according time settings of CHANNEL A and CHANNEL B).
CHANNEL B
FACTORY SETTING: 3.0s
This parameter can be set if two materials are conveyed and mixed.
Material B is drawn for this time period. The suction time for vacuum loaders is automatically corrected
by the program (according time settings of CHANNEL A and CHANNEL B).
The key can be used at any time to return from this screen back to the screen with the
DRYING PARAMETERS.